Overview
The PMC200S ac multi-function energy meter is a compact panel-mounted power measurement and control instrument that integrates data acquisition and control functions and replaces a variety of instruments, relays, transformers, and other components to meet the needs of various application scenarios via extended DI/DO, AI/AO modules.
Â
Products Description
As a board mounted instrument, PMC200S accomplishes precise estimation of exceptionally nonlinear burdens in view of the estimation of rms. High level lattice recurrence synchronous examining innovation empowers it to precisely gauge an extensive variety of force boundaries, including voltage/current, recurrence, power, power component, energy and current/voltage sounds.
Contrasted and customary energy meters, PMC200S has the two information procurement and control capabilities, minimal size, simple to send and cost saving elements, and can be generally utilized in energy the executives frameworks, substation mechanization, dissemination network robotization, local area power circulation, modern computerization, power plant power frameworks, clever structures, keen appropriation boards, high and low voltage switchgear and different situations.
By utilizing the PMC200S, you can acquire bits of knowledge into power load conditions, recognize top energy utilization periods, and go to designated energy-saving lengths. Our item offers a 485 correspondence interface, permitting you to communicate with different gadgets and brilliant frameworks, empowering more savvy energy the executives.
We are focused on furnishing you with far reaching and solid energy observing and the executives arrangements, assisting you with accomplishing energy-saving and discharge decrease objectives while working on cost-viability. Pick our multifunctional meter, and you will appreciate trend setting innovation, helpful activity, and a solid quality assurance.
Â
Features
Â
Main features | |
Instantaneous RMS | |
I | each phase and conjunction, average |
ULN/ULL | each phase and conjunction, average |
kWh, kvarh, kVAh | each phase and the sum of three phases |
PF | each phase and the sum of three phases |
f | 45~65Hz |
Maximum/minimum value | |
Max/min rms I | |
Max/min rms ULN | |
Max/min total kWh, kvarh, kVAh | |
Max/min total PF | |
Max/min f | |
Max/min THD I and THD U | |
Demand and peak demand value | |
Current per phase | current value/peak/month end peak |
Total kWh, kvarh, kVAh | current value/peak/month end peak |
Energy | |
Input/output/total kWh | 1 pulse output |
Input/output/total kvarh | 1 pulse output |
kVAh | |
Compound rate of electrical energy | |
8 recharge periods, 4 rates can be set | |
Power quality | |
Total Harmonic Distortion Rate (THD) | current and voltage |
1st-31st harmonic analysis | current and voltage |
Voltage crest factor CF and current K coefficient | |
Event logging | |
100 SOE event records | |
Alarm system | |
8 configurable limit alarm channels | |
4 configurable logical alarm channels | |
Communication | |
RS-485 /MODBUS-RTU | |
Display | |
STN LCD display | |
Real-time clock | |
Year, month, day, minute, second | |
Other | |
Program online upgrade supported |
Â
Optional features |
Digital Input (DI) module (optional) |
4 switching inputs |
Digital Output (DO) module (optional) |
2 relay outputs, which can be set by local overrun alarm or controlled remotely |
Analog Input (AI)/Output (AO) module (optional) |
A total of 2 channels. Optional 4-20mA DC analog input, 0-5V DC analog input, 4-20mA DC analog output |
Â
Specifications
Â
Electrical characteristics | ||
System | Three-phase three-wire AC system, three-phase four-wire AC system; | |
Sample rate | 128 samples per cycle | |
Data refresh rate | 1s | |
Measurement accuracy | Current | ±0.2%FS |
Voltage | ±0.2%FS | |
Power | 0.5S | |
Frequency | ±0.001Hz | |
Active energy | 0.5S | |
Reactive energy | 1.0S | |
DC input (AI) | 0.5% FS | |
DC output (AO) | 0.5% FS | |
Voltage input | Measure voltage | 3*220/380V(Direct input) |
3*57.7/100V (PT secondary) | ||
Overload | 1.2x/continuous | |
Input impedance | 300KΩ | |
Current input | Measure current | 5A (CT secondary) or 1A (CT secondary) |
Overload | 1.2x/continuous | |
Input impedance | <0.1Ω | |
Digital input | Operating voltage | 12~24VDC |
Input impedance | 12KΩ | |
Isolation voltage | 2KV | |
Digital output | Node type | Mechanical contacts |
Node capacity | 220 VAC/5Aã€30 VDC/5A | |
4-20mA DC input measurement | Measure current | 4~20mA |
Allowed overload capacity | 1.2x/continuous | |
Input impedance | 10Ω | |
Isolation voltage | 2KV | |
0-5V DC input measurement | Measure voltage | 0~5V |
Allowed overload capacity | 1.2x/continuous | |
Input impedance | 12.5KΩ | |
Isolation voltage | 2KV | |
4-20mA DC output | Open-circuit voltage | 15VDC |
Load capacity | ≤600Ω | |
Isolation voltage | 2KV | |
Working power supply | AC | 100~240VAC/45~65Hz |
DC | 100~375 VDC | |
power consumption | < 3W | |
Mechanical characteristic | ||
Weight | 0.5kg | |
IP protection rating | Instrument panel IP52, instrument body IP30 | |
Size | host | 96 *96 * 72 mm |
Host + module | 96 * 96 * 120 mm | |
Operating temperature | display | -20~70°C |
Instrument | -25~70°C | |
Storage temperature | instrument + display | -40~85°C |
Humidity | 5% ~ 90%RH, non-condensing | |
Electromagnetic compatibility | ||
Electrostatic discharge | IEC 61000-4-2,Level 4 | |
Fast transient | IEC 61000-4-4,Level 4 | |
Surges | IEC 61000-4-5,Level 3 | |
Magnetic fields | IEC 61000-4-8,Level 3 | |
Electrical insulation | ||
Insulation resistance | GB/T13729,>50MΩ | |
AC voltage | GB/T13729, AC 2KV 50Hz /1min | |
Impulse voltage | GB/T13729,5KV,1.2/50us |
Â
Dimensions
The size of the instrument is shown below.
Â
Mounting
Insert the meter into the 90mm*90mm cutting slot and secure it with the buckle.
Â
Application
As shown in the figure below, the instrument is in the collection layer, responsible for the measurement and collection of power data of each circuit, at the same time, the instrument equipped with DI/DO, AI/AO module can realize switch status monitoring, relay output, DC voltage and current input monitoring and transmitter, can also be customized according to your demands.
Ordering guide
Â
Model code: PMC200S-(1)-(2)-(3)-(4)-(5). | |
(1)Input voltage and current: | |
1 | 57.7/100V rated measurement voltage, 5A rated measurement current. |
2 | 57.7/100V rated measurement voltage, 1A rated measurement current. |
3 | 220/380V rated measurement voltage, 5A rated measurement current. |
4 | 220/380V rated measurement voltage, 1A rated measurement current. |
(2)Power supply: | |
1 | Power supply: 85~264 VAC/45~65Hz, 100~300 VDC. |
(3)DI: | |
0 | No DI |
4 | 4-way DI |
(4)Optional: | |
0 | No optional |
1 | Optional 1 relay output (RL1+, RL1-port). |
2 | Optional 2 relay outputs |
(5)AI&AO: | |
ab | "a" is for selecting the AI/AO module for AIO1 port, and "b" is for selecting the AI/AO module for AIO2 port. The optional modules are: 0 - None 1 - 5V DC analog input measurement (AI) 2 - 420mA DC analog input measurement (AI) 3 - 4~20mA DC analog output (AO) For example, "ab = 00" means the AI/AO module is not selected for AIO1 port, and the AI/AO module is not selected for AIO2 port. "ab = 12" means the AIO1 port is equipped with the 5V DC analog input measurement module, and the AIO2 port is equipped with the 420mA DC analog input measurement module. |
Â
About Us
Established in 2014, Kingnen Co., Ltd. is an expert maker of force framework investigating hardware and canny estimation and control instruments. We work in autonomous innovative work, creation, and deals. We are a public cutting edge undertaking and have gotten the Shenzhen Twofold Delicate Certificate. Our organization is situated at Building Compact disc, Block 4, Tian'an Computerized City, Shenzhen, China, involving 1,500 square meters of office space and a 3,000 square meter production line.
Â
After-Sales Service
To ensure your pleasure, we guarantee to offer excellent product quality assurance and thorough after-sales service support. You can take advantage of long-term warranty benefits because we promise clear warranty terms and completely uphold our contractual obligations. We offer free professional services to handle all of your concerns during the predetermined after-sales service period. We may discuss fair prices with you even after the service period is over to make sure you continue to get high-quality service without any additional costs.
Â
FAQ
1. Do we need extension modules?
Although input/ output extension modules are not necessary, they do allow for transmitters, DC voltage and current input monitoring, relay output, and switch status monitoring. Depending on your unique needs, we might also provide modification.
Â
2. On how many PMC200S can a single acquisition node be configured?
A Category 5e shielded twisted pair cable can be used to connect up to 32 devices to a single node. The bus really should not be longer than 1200 meters if no repeaters are used.
Â
http://www.kingnenmeter.com/
-
Polyether Polyol Used for Pipe Insulation
price: Negotiable
-
Primer for Metal Surfaces
price: Negotiable
-
Pressure Transducer with Digital Display
price: Negotiable
-
PVC Air Blowing Slide Slipper
price: Negotiable
-
Hexagon Drill Tail Screw
price: Negotiable
-
Detolf Greenhouse
price: Negotiable